Tube capillaire
Utiliser cette image
Puis-je réutiliser cette image sans autorisation? Oui
Les images sur le portail de la collection d’Ingenium ont la licence Creative Commons suivante :
Copyright Ingenium / CC BY-NC-ND (Attribution-NonCommercial 4.0 International (CC BY-NC 4.0)
ATTRIBUER CETTE IMAGE
Ingenium,
1991.0304.001
Permalien:
Ingenium diffuse cette image sous le cadre de licence Creative Commons et encourage son téléchargement et sa réutilisation à des fins non commerciales. Veuillez mentionner Ingenium et citer le numéro de l’artefact.
TÉLÉCHARGER L’IMAGEACHETER CETTE IMAGE
Cette image peut être utilisée gratuitement pour des fins non commerciales.
Pour un usage commercial, veuillez consulter nos frais de reproduction et communiquer avec nous pour acheter l’image.
- TYPE D’OBJET
- MICROHEMATOCRIT/HEPARANIZED
- DATE
- 1960–1980
- NUMÉRO DE L’ARTEFACT
- 1991.0304.001
- FABRICANT
- Clay-Adams Inc.
- MODÈLE
- PRE-CAL
- EMPLACEMENT
- New York, New York, United States of America
Plus d’information
Renseignements généraux
- Nº de série
- S/O
- Nº de partie
- 1
- Nombre total de parties
- 1
- Ou
- S/O
- Brevets
- S/O
- Description générale
- CONTAINER, SYNTHETIC PLASTIC/ CAPILLARY TUBES, GLASS/ SOLID TUBES, SYNTHETIC PLASTIC
Dimensions
Remarque : Cette information reflète la taille générale pour l’entreposage et ne représente pas nécessairement les véritables dimensions de l’objet.
- Longueur
- 9,0 cm
- Largeur
- 3,0 cm
- Hauteur
- 3,0 cm
- Épaisseur
- S/O
- Poids
- S/O
- Diamètre
- S/O
- Volume
- S/O
Lexique
- Groupe
- Technologie médicale
- Catégorie
- Matériel médical
- Sous-catégorie
- S/O
Fabricant
- Ou
- Clay Adams
- Pays
- United States of America
- État/province
- New York
- Ville
- New York
Contexte
- Pays
- Canada
- État/province
- Nouveau-Brunswick
- Période
- C.1960-PRESENT
- Canada
-
A test which did not require the purchase of expensive equipment & could be easily set up in any laboratory. This method was used in many small laboratories for several years (c.1960-1980's), especially if cost or work volume prohibited the purchase of more sophisticated machines. “This artifact is part of a collection used in l’Hôpital de l’Assomption in Grand Falls/Grand Sault, New Brunswick. The hospital was run by the Secular Institute of The Oblate Missionaries of Mary Immaculate (OMMI), from 1952-1964. OMMI is a large organisation which ran residential schools across Canada and the Secular Institute is one arm of that larger organisation [1].The artifacts in this collection were curated by the Secular Institute (sometimes referred to as the “Oblates”), specifically Fabienne Rinfret, who was one of the original 10 nurses working at the hospital when it opened [2]. They were purchased by The Canada Science and Technology Museum in 1991, only months before OMMI made their first apology for their role in running residential schools [3]. The artifacts in this collection are common examples of medical objects, which were manufactured in many places inside and outside of Canada. What makes them unique is their context, they were used in this hospital by the “Oblate” nurses. The hospital was previously called l’Hôpital d’Emard and run by Mme. Emard, Mr. Emard (who was blind), and a few other staff [4]. The “Oblates” took over in 1952 and ran the hospital until May 31st 1964 upon the opening of Grand Falls General Hospital Incorporated, which was run by the Religieuses Hospitalières de St-Joseph. The Cataract Weekly (Grand Falls’ bilingual newspaper) reported that all 55 staff members were hired on at the new hospital and most of the equipment was transferred there as well [5]. After only a year and a half the Secular Institute had 200 members, most of whom had passed through the Mother House at l’Hospital de l’Assomption. Many members were nurses working at hospitals in New Brunswick and Québec. Others worked as teachers, housekeepers, and nurses at presbyteries [6]. From the Secular Institute’s history written in 2015, Malenfant states: “[t]he Institute did not limit itself to a particular type of works” and “[t]he intern members devoted themselves in varied works: hospitals, schools, classical colleges, dispensaries, secretariats, social services, homes for young girls, for convalescents or for the elderly, bookstores, […] etc.” [2]. There were no residential schools in New Brunswick, however, Shubenacadie Residential School ran in Nova Scotia from 1930 and 1967 [7]. From 1956-1967 it was managed by the Oblate Missionaries of Mary Immaculate [8]. There was also a segregated hospital and day school, Tobique Indian Hospital (also known as St. Ann’s Teacherage and Hospital) in Tobique, NB, which was run by the Sisters of Charity from 1928-1981 [9] [10].” [Ref 3] - Fonction
-
THE CAPILLARY TUBES WERE USED IN A TEST TO DETERMINE A PATIENT'S HEMATOCRIT VALUE. THIS VALUE WAS USEFUL IN DIAGNOSING ANEMIA. BLOOD WAS DRAWN INTO THE TUBES WHICH WERE THEN SEALED & CENTRIFUGED FOR A SPECIFIED TIME & SPEED. THE RESULT WAS DETERMINED BY A READING TAKEN FROM A SCALE (REF.2) - Technique
-
A FAST METHOD OF DETERMINING HEMATOCRIT VALUE WHICH COULD BE DONE WITH A FINGER PRICK AVOIDING THE NEED FOR VENIPUNCTURE IN INFANTS. THIS METHOD PROVIDED A RELIABLE RESULT UNDER MOST CIRCUMSTANCES, & COULD BE SET UP IN SMALL LABORATORIES. - Notes sur la région
-
Inconnu
Détails
- Marques
- TUBES HAVE A BLACK CALIBRATION MARK/ PRINTED ON CONTAINER 'PRE-CAL [REGISTERED TRADE MARK SYMBOL]/ MICRO-HEMATOCRIT TUBES/ HEPARANIZED/ CALIBRATED 60mm. FROM END/ LENGTH 75mm.-I.D. 0.5-0.6 mm. - 0.0. 1.3-1.4mm/ SELECTED LOW TAPER - FIRE POLISHED ENDS/ SPECIALLY CALIBRATED FOR/ ADAMS READACRIT [REGISTERED TRADE MARK SYMBOL] CENTRIFUGE/ DRAW BLOOD TO 60mm CALIBRATION MARK. SEAL/ OPPOSITE END WITH ADAMS SEAL EASE OR FLAME/ SEAL. CENTRIFUGE AND READ %HEMATOCRIT/ DIRECTLY FROM SCALE IN HEAD OF CENTRIFUGE./ 100 TUBES NO.A-2937/ CLAY-ADAMS, INC./ NEW YORK 10, N.Y./ PAT. PENDING/ MADE IN U.S.A.' [COMPANY LOGO].
- Manque
- NONE
- Fini
- CONTAINER, CLEAR SYNTHETIC PLASTIC/ CAP YELLOW PLASTIC/ CAPILLARY TUBES, CLEAR GLASS/ SOLID TUBES, BLUE PLASTIC
- Décoration
- S/O
FAIRE RÉFÉRENCE À CET OBJET
Si vous souhaitez publier de l’information sur cet objet de collection, veuillez indiquer ce qui suit :
Clay-Adams Inc., Tube capillaire, vers 1960–1980, Numéro de l'artefact 1991.0304, Ingenium - Musées des sciences et de l'innovation du Canada, http://collection.ingenium.ca/fr/id/1991.0304.001/