Voltmètre
Utiliser cette image
Puis-je réutiliser cette image sans autorisation? Oui
Les images sur le portail de la collection d’Ingenium ont la licence Creative Commons suivante :
Copyright Ingenium / CC BY-NC-ND (Attribution-NonCommercial 4.0 International (CC BY-NC 4.0)
ATTRIBUER CETTE IMAGE
Ingenium,
1982.0069.001
Permalien:
Ingenium diffuse cette image sous le cadre de licence Creative Commons et encourage son téléchargement et sa réutilisation à des fins non commerciales. Veuillez mentionner Ingenium et citer le numéro de l’artefact.
TÉLÉCHARGER L’IMAGEACHETER CETTE IMAGE
Cette image peut être utilisée gratuitement pour des fins non commerciales.
Pour un usage commercial, veuillez consulter nos frais de reproduction et communiquer avec nous pour acheter l’image.
- TYPE D’OBJET
- Portable/AC DC/Thermocouple/Double range
- DATE
- 1947
- NUMÉRO DE L’ARTEFACT
- 1982.0069.001
- FABRICANT
- Weston Electrical Instrument Corp.
- MODÈLE
- 622
- EMPLACEMENT
- Newark, New Jersey, United States of America
Plus d’information
Renseignements généraux
- Nº de série
- 8463
- Nº de partie
- 1
- Nombre total de parties
- 1
- Ou
- S/O
- Brevets
- S/O
- Description générale
- Metal/ Bakelite/ Glass/ Leather.
Dimensions
Remarque : Cette information reflète la taille générale pour l’entreposage et ne représente pas nécessairement les véritables dimensions de l’objet.
- Longueur
- 19,6 cm
- Largeur
- 21,8 cm
- Hauteur
- 10,4 cm
- Épaisseur
- S/O
- Poids
- S/O
- Diamètre
- S/O
- Volume
- S/O
Lexique
- Groupe
- Énergie-électrique
- Catégorie
- Mesurage
- Sous-catégorie
- S/O
Fabricant
- Ou
- Weston
- Pays
- United States of America
- État/province
- New Jersey
- Ville
- Newark
Contexte
- Pays
- Canada
- État/province
- Ontario
- Période
- 1947+
- Canada
-
Used at the National Research Laboratories for Electrical Engineering until 1974, when it was found to be defective. - Fonction
-
Used for precision laboratory measurements of voltages up to 1000V., D.C. or A.C., up to 5000 cycles. - Technique
-
Good example of precision instruments of the 1940s. The first Weston meter to incorporate an internal easily replaceable vacuum type thermo element (introduced in 1937). Previously, thermo instruments either used an external heating element or an internal one which was housed inside the case and needed to be sent back to the manufacturer for replacement. In this case, only the thermo element needs to be sent to the manufacturer. The manufacturer then sends a new one along with a correction chart because each thermo element is slightly different and the meter and thermo element must be calibrated together. This artefact has two correction charts in a pouch in the lid, dated to 1947. The replacement of wooden cases by Bakelite ones in this kind of accurate laboratory instrument is due to the cheapness and easy maintenance of the synthetic as well as to its insulating and electric properties. The finger operated Bakelite zeroing knob represents a departure from previous models that had a screw. As with the removable thermo element, ease of use was emphasized in this meter. - Notes sur la région
-
Inconnu
Détails
- Marques
- NRC sticker & stencilled inventory number on case/ Mfr's plate below dial/ Strip of tape marked 'Defective, May 1976, P. Mougeot'
- Manque
- No input leads provided.
- Fini
- Black case. White dial face.
- Décoration
- S/O
FAIRE RÉFÉRENCE À CET OBJET
Si vous souhaitez publier de l’information sur cet objet de collection, veuillez indiquer ce qui suit :
Weston Electrical Instrument Corp., Voltmètre, vers 1947, Numéro de l'artefact 1982.0069, Ingenium - Musées des sciences et de l'innovation du Canada, http://collection.ingenium.ca/fr/id/1982.0069.001/
RÉTROACTION