Moiré apparatus
Use this image
Can I reuse this image without permission? Yes
Object images on the Ingenium Collection’s portal have the following Creative Commons license:
Copyright Ingenium / CC BY-NC-ND (Attribution-NonCommercial 4.0 International (CC BY-NC 4.0)
ATTRIBUTE THIS IMAGE
Ingenium,
1998.0276.001
Permalink:
Ingenium is releasing this image under the Creative Commons licensing framework, and encourages downloading and reuse for non-commercial purposes. Please acknowledge Ingenium and cite the artifact number.
DOWNLOAD IMAGEPURCHASE THIS IMAGE
This image is free for non-commercial use.
For commercial use, please consult our Reproduction Fees and contact us to purchase the image.
- OBJECT TYPE
- N/A
- DATE
- 1978
- ARTIFACT NUMBER
- 1998.0276.001
- MANUFACTURER
- OTAL PRECISION CO. LTD.
- MODEL
- MOIRE CONTOURGRAPHE 40-20-8MS
- LOCATION
- Ottawa, Ontario, Canada
More Information
General Information
- Serial #
- 78-502
- Part Number
- 1
- Total Parts
- 2
- AKA
- N/A
- Patents
- N/A
- General Description
- METAL COMPONENTS, SAVE FIBRE STRINGS AND SOME MINOR SYNTHETIC FITTINGS, ETC. RUBBER (?) COVERED ELECTRICAL CORDS.
Dimensions
Note: These reflect the general size for storage and are not necessarily representative of the object's true dimensions.
- Length
- 107.0 cm
- Width
- 98.0 cm
- Height
- 232.5 cm
- Thickness
- N/A
- Weight
- N/A
- Diameter
- N/A
- Volume
- N/A
Lexicon
- Group
- Medical Technology
- Category
- Medical equipment
- Sub-Category
- N/A
Manufacturer
- AKA
- OTAL
- Country
- Canada
- State/Province
- Ontario
- City
- Ottawa
Context
- Country
- Canada
- State/Province
- Ontario
- Period
- THIS INSTRUMENT WAS USED C. 1978- 1980S.
- Canada
-
DEVELOPED JOINTLY BY DR. TED BLACHUT OF NRC AND DR. ARMSTRONG OF THE OTTAWA CIVIC AND GENERAL HOSPITALS IN THE MID 1970S, AND MFD IN LIMITED QUANTITIES BY OTAL PRECISION CO. LTD., OTTAWA. TECHNOLOGY USED IN CANADIAN HOSPITALS AND SCHOOLS FOR SCREENING PURPOSES. ACCORDING TO DONOR THIS UNIT USED BY QUEEN'S & NRC STAFF IN JOINT EXPERIMENTS. - Function
-
TO DETECT IRREGULARITIES IN THE CURVATURE OF THE HUMAN SPINE. - Technical
-
DIAGNOSTIC INSTRUMENT DESIGNED TO SCREEN PATIENTS, ESPECIALLY CHILDREN, SUFFERING DEFORMITY OF THE SPINE. LIGHT SHINING ON THE SUBJECT'S BACK, THROUGH THE SLITS FORMED BY STRINGS ON UNIT, CREATED MOIRE PATTERNS: ASSYMETRIES INDICATED IRREGULARITY. SIMPLE TO OPERATE, IT WAS USED BY NURSES AND/OR TECHNICIANS. SUSPECT RESULTS WERE RECORDED PHOTOGRAPHICALLY, AND THE IMAGES PROVIDED TO A PHYSICIAN FOR FOLLOW-UP AND/OR FURTHER EXAMINATION. - Area Notes
-
Unknown
Details
- Markings
- Plate on lower front of instrument reads " OTAL/ PRECISION COMPANY LIMITED/ OTTAWA ONTARIO CANADA ". Plate on lower right side of unit back reads " MOIRE CONTOURGRAPHE/ MODEL NO. 40-20-8MS/ SERIAL NO. 78-502 ". Panel containing text mounted on centre front, to right of clock, reads "K62/ MOIRE TOPOGRAM/ OTAL CONTOURGRAPH/ MODEL MS 20 40/ FIDUCIAL TARGETS X 475 MM Y 700 MM/ FIDUCIAL STRINGS INTERSECT ON CAMERA AXIS AT XYZ ORIGIN/ Y [A]XIS IS VERTICAL/ X AXIS IS HORIZONTAL/ CONTOUR INTERVAL Z AXIS 5 MM NOMINAL/ GRID TO CAMERA 1700 MM/ CAMERA TO LAMP 10 MM/ GRID PITCH 2 MM Y AXIS ". Clock face reads " Ingraham " & " MADE IN CANADA ".
- Missing
- LIGHT SOURCE; SOME ELECTRONIC COMPONENTS MISSING. From CA of 10/24/2000 by Myles Bailey: Yes - There are missing bolts for the standing platform. There are two allen bolts holding nothing and some electrical cords not in there respective plugs.
- Finish
- FLAT BLACK FINISH OVERALL; WHITE MARKINGS, FIDUCIAL LINES, ETC.
- Decoration
- N/A
CITE THIS OBJECT
If you choose to share our information about this collection object, please cite:
OTAL PRECISION CO. LTD., Moiré apparatus, 1978, Artifact no. 1998.0276, Ingenium – Canada’s Museums of Science and Innovation, http://collection.ingenium.ca/en/id/1998.0276.001/
FEEDBACK
Submit a question or comment about this artifact.
More Like This



































































































