- OBJECT TYPE
- NEONATAL/PORTABLE
- DATE
- 1991
- ARTIFACT NUMBER
- 1995.1011.001
- MANUFACTURER
- OHIO MEDICAL PRODUCTS
- MODEL
- Unknown
- LOCATION
- Madison, Wisconsin, United States of America
More Information
General Information
- Serial #
- AEFD00005
- Part Number
- 1
- Total Parts
- 2
- AKA
- N/A
- Patents
- N/A
- General Description
- METAL/ SYNTHETIC
Dimensions
Note: These reflect the general size for storage and are not necessarily representative of the object's true dimensions.
- Length
- 53.0 cm
- Width
- 53.0 cm
- Height
- 103.0 cm
- Thickness
- N/A
- Weight
- N/A
- Diameter
- N/A
- Volume
- N/A
Lexicon
- Group
- Medical Technology
- Category
- Medical equipment
- Sub-Category
- N/A
Manufacturer
- AKA
- OHIO
- Country
- United States of America
- State/Province
- Wisconsin
- City
- Madison
Context
- Country
- North America
- State/Province
- Unknown
- Period
- Unknown
- Canada
-
EXAMPLE OF EQUIPMENT USED IN A CANADIAN HOSPITAL - Function
-
USED TO MAINTAIN ARTIFICAL RESPIRATION; OR FOR PROTECTING THE RESPIRATORY TRACT WITH OR WITHOUT EQUIPMENT SUPPLYING OXYGEN OR AIR. THIS ONE WAS DESIGNED FOR TREATING NEWBORN INFANTS. - Technical
-
A SPECIFICALLY DESIGNED UNIT FOR TREATMENT OF NEWBORNS - Area Notes
-
Unknown
Details
- Markings
- .1 MFG'S PLATE:'Ohio/ NEONATAL VENTILATOR/ VOLTS 120AC/ AMPS.4/ HZ 50/60/ SERIAL NUMBER/ AEFD00005''CAUTION: FEDERAL (U.S.A.)/ LAW RESTRICTS THIS DEVICE/ TO SALE BY OR ON THE/ ORDER OF A PHYSICIAN/ MADE IN THE U.S.A./ Ohio Medical Products/ MADISON, WISCONSIN. 53701/ A DIVISION OF AIRCO INC./ AIRCO'/ FRONT PANEL: 'Ohio/ NEONATAL/ RESPIRATOR/ AIRWAY PRESSURE/ PATIENT DELIVERY LINE/ TO EXHALATION VALVE/ TIDAL VOLUME CUBIC CENTIMETERS'/ DESIGNATIONS ON CONTROL PANEL INCLUDE: 'AIRWAY PRESSURE/ PATIENT PRESSURE LIMIT/ INSPIRATORY FLOW/ EXPIRATORY TIME/ MANUAL INSPIRATOR/ PATIENT TRIGGERING EFFORT/ % O 2 CONCENTRATION/ DEEP BREATH INTERVAL'/*
- Missing
- UNKNOWN
- Finish
- .1 BODY COVERED ON 3 SIDES WITH BEIGE SYNTHETIC COVERING - FRONT WHITE PANEL WITH CHROME TRIM - TOP SECTION PAINTED LIGHT BROWN WITH TOP CONTROL PANEL BLACK WITH SILVERPRINTING; CHROME AND BLACK KNOBS/.2 GREEN, BLACK, & BROWN TUBES WITH METAL CHAMBERS ATTACHED
- Decoration
- N/A
CITE THIS OBJECT
If you choose to share our information about this collection object, please cite:
OHIO MEDICAL PRODUCTS, Respirator, before 1991, Artifact no. 1995.1011, Ingenium – Canada’s Museums of Science and Innovation, http://collection.ingenium.ca/en/id/1995.1011.001/