Processor, tissue

Use this image

Can I reuse this image without permission? Yes

Object images on the Ingenium Collection’s portal have the following Creative Commons license:

Copyright Ingenium / CC BY-NC-ND (Attribution-NonCommercial 4.0 International (CC BY-NC 4.0)

ATTRIBUTE THIS IMAGE

Ingenium, 1986.0902.001
Permalink:

Ingenium is releasing this image under the Creative Commons licensing framework, and encourages downloading and reuse for non-commercial purposes. Please acknowledge Ingenium and cite the artifact number.

DOWNLOAD IMAGE

PURCHASE THIS IMAGE

This image is free for non-commercial use.

For commercial use, please consult our Reproduction Fees and contact us to purchase the image.

OBJECT TYPE
AUTOMATIC
DATE
1979
ARTIFACT NUMBER
1986.0902.001
MANUFACTURER
TECHNICON INSTRUMENTS CORP.
MODEL
AUTOTECHNICON DUO 2A
LOCATION
Tarrytown, New York, United States of America

More Information


General Information

Serial #
GG 007929
Part Number
1
Total Parts
1
AKA
N/A
Patents
N/A
General Description
METALS (PROBABLY INCLUDES ALUMINUM & STAINLESS STEEL); SYNTHETIC CHEMICAL PORTS & FITTINGS, HOSES, CORDS & PLUGS, ETC. PORCELAIN PARAFFIN BATH CHAMBERS

Dimensions

Note: These reflect the general size for storage and are not necessarily representative of the object's true dimensions.

Length
65.0 cm
Width
55.0 cm
Height
90.0 cm
Thickness
N/A
Weight
N/A
Diameter
N/A
Volume
N/A

Lexicon

Group
Medical Technology
Category
Medical equipment
Sub-Category
N/A

Manufacturer

AKA
TECHNICON
Country
United States of America
State/Province
New York
City
Tarrytown

Context

Country
Canada
State/Province
Ontario
Period
THIS UNIT USED BETWEEN 1979-1986
Canada
EXAMPLE OF TISSUE PROCESSING EQ. USED IN HISTOLOGY LAB. OF LARGE CANADIAN HOSPITAL, THE OTTAWA CIVIC HOSPITAL.
Function
USED IN HISTOLOGY LABS FOR TISSUE PROCESSING WORK
Technical
POPULAR MAKE AND MODEL OF TIME-TYPE TISSUE PROCESSOR. CONSIDEREDOBSOLETE BY CIVIC HOSPITAL IN 1986. THIS MACHINE FITTED WITH 20 REAGENT PORTS & 4 PARAF IN BATH PORTS FOR IMPREGNATING TISSUE SAMPLES. PROGRAM CONTROL DISKS ALLOW UNIT TO BE OPERATED OVERNIGHT, ON WEEKENDS, ETC. UNATTENDED. REPLACED BY COMPUTERIZED EQ.
Area Notes
Unknown

Details

Markings
MFR'S PLATE ON BASE, BETWEEN ACCESS DOORS, INCLUDES INSTRUCTIONS 'FOR ACCESS TO BREAKERS' & FOLLOWING INFO.: 'Autotechnicon Duo/ Mod. 2A/ Autotechnicon Duo is a trademark registered by Technicon/ Corporation for automatic tissue processing machines. Registered U.S. patent office and foreign countries, covered/ by one or more of the following United States patents:/ 2,583,379 2,741,221 2,783,180 2,800,102 2,810,366 2,845,044 2,845,045 2,869,509 2,872,893 2,872,894 2,894,482 2,925,820 2,960,962 3,110,627 3,227,130 3,338,207 3,350,220 3,388,687 D 179,297 D 179,298/ and foreign patents. Also, United States and Foreign Pat-/ ents pending./ SERIAL NO. GG 007929 D/ 115 VOLTS 7 AMPS. 60 Hz/ [LOGO]/ TECHNICON CORPORATION/ TARRYTOWN, NEW YORK 10591, U.S.A.'/ LABEL ABOVE: 'PROPERTY TAG/ ASSET NO. 3-4639'. Instructions "FOR ACCESS TO BREAKERS" appear as follows: "PUSH UP/ AND RELEASE/ TO START"; "PUSH DOWN/ AND RELEASE/ TO STOP/ WHERE DESIRED/ PUSH UP AND RELEASE AGAIN/ AND MACHINE AUTOMATICALLY/ WILL RETURN TO OPERATING/ POSITION/ 1 HR OFF 24 HR". Label inside left panel reads: " WARNING/ ELECTRICAL SHOCK HAZARD. COVERS/ OR PANEL(S) SHOULD BE REMOVED/ BY QUALIFIED PERSONNEL ONLY.". Identical label appears inside right panel, with time delay mechanism and automatic timer disc. All controls labelled. Timer graduated by 1 hr. intervals, from 0- 72. 1 disc on machine, labelled and bears mfr's markings. 2nd disc bears mfr's markings; handwritten label taped to centre reads: " WEEKEND-DUO/ START-12-NOON ". Mfr's decal above electrical cord reads: "AUTOTECHNICON DUO/ SN [blank]/ 115 V 7 A 60 Hz/ P/N 103-A004/ TECHNICON INSTRUMENTS CORPORATION/ TARRYTOWN, NEW YORK 10591, U.S.A./ U.S. AND FOREIGN PATENTS AND PATENTS PENDING/ [ LOGO ]/ MEDICAL EQUIPMENT [ UNDERWRITERS LABORATORIES LOGO ] LISTED 134 D". Label above reads: "WARNING/ THIS DEVICE IS EQUIPPED WITH A/ GROUNDING TYPE ELECTRICAL PLUG/ FOR YOUR PROTECTION AGAINST/ ELECTRICAL SHOCK HAZARD, AND/ SHOULD ONLY BE ATTACHED TO A/ PROPERLY GROUNDED RECEPTACLE." Ontario Hydro label, above, reads: "[ logo ]/ ontario hydro/ electrical/ approval/ by special inspection- series K". All controls labelled. Decal on base, to right, reads: " WARNING/ BEFORE OPERATING THIS SYSTEM, PLEASE READ AND UNDERSTAND THE OPERATOR'S INSTRUCTION MANUAL/ SUPPLIED. THE FOLLOWING ARE SOME OF THE PRECAUTIONS TO BE OBSERVED./ 1. PLACE THIS INSTRUMENT IN AN UNCLUTTERED/ AREA. ALLOW ADEQUATE SPACE. / 2. THIS INSTRUMENT MUST BE USED WITH AN/ EXHAUST SYSTEM CAPABLE OF REMOVING/ 500 FT3/MINUTE (CFM) OF AIR./ 3. LOCATE THE INSTRUMENT AWAY FROM ANY AREA/ IN WHICH THERE ARE OPEN FLAMES (INCLUDING/ PILOT LIGHTS)./ 4. THIS INSTRUMENT HAS BEEN MANUFACTURED TO/ MEET THE REQUIREMENTS OF UNDERWRITER'S LABORATORIES, INC. (U.L.). TECHNICON REAGENTS/ SPECIFIED IN THE OPERATOR'S MANUAL HAVE/ BEEN TESTED BY U.L. , AND THESE REAGENTS ARE/ DEEMED SAFE FOR USE WITH THIS INSTRUMENT. USE OF REAGENTS AND MINERAL OIL OTHER/ THAN SPECIFIED NULLIFIES THE U.L. LISTING OF/ THIS INSTRUMENT./ 5. USE ONLY TECHNICON REAGENTS SINCE THEY/ HAVE FLASH POINTS (TAG OPEN CUP METHOD) HIGHER THAN 80 DEGREES F./ *6. FOLLOWING IS A PARTIAL LIST OF SOME OF THE/ REAGENTS THAT SHOULD NOT BE USED IN THIS/ UNIT:/ BUTYL ACETATE/ AMYL ACETATE/ KETONE/ *TECHNICON C-650/ *TECHNICON C-550/ DIOXANE/ CHLOROFORM/ TETRAHYDROFURAN/ 7. THE REAGENTS RECOMMENDED ARE FLAM-/MABLE AND TOXIC AND SHOULD BE HANDLED/ ACCORDINGLY. *8. CHECK THE OIL LEVEL DAILY ( AUTOTECHNICON ULTRA ONLY ). DO NOT OPERATE THIS SYSTEM/ UNLESS THE OIL IS MAINTAINED AT ITS PROPER / LEVEL, OR IF MORE THAN ONE BEAKER HAS BEEN/ REMOVED FROM THE PROCESSING SECTION, OR/ IF THE BEAKER HAS BEEN REMOVED FROM THE PARAFFIN SECTION, UNLESS THE HEATER/ SWITCHES ARE IN THE OFF POSITION./ *9. IN THE EVENT MAINTENANCE OR TROUBLE-/ SHOOTING HAS TO BE PERFORMED ON AUTO-/ TECHNICON ULTRA INSTRUMENTS, IT IS NECES-/ SARY TO DISENGAGE THE TISSUE SAFEGUARD/ TIME DELAY DEVICE. THIS IS DONE TO ELIMINATE/ THE POSSIBILITY OF INJURY TO THE OPERATOR/ OR DAMAGE TO THE INSTRUMENT DUE TO THE/ TISSUE SAFEGUARD TIME DELAY DEVICE BEING/ ENERGIZED DURING THE MAINTENANCE OR/ TROUBLE SHOOTING FUNCTION. TO DISENGAGE/ THE TISSUE SAFEGUARD TIME DELAY DEVICE,/ SET THE RUN-OFF MOMENTARY SWITCH TO OFF./ REMOVE THE POWERCORD FROM THE POWER/ RECEPTACLE TO AVOID SHOCK HAZARD./ 10. KEEP THIS INSTRUMENT CLEAN. WIPE SPILLAGE/ IMMEDIATELY. FOLLOW THE MAINTENANCE PRO-/ CEDURE RECOMMENDED./ NOTE: * (ASTERISK) DENOTED PARAGRAPHS AND/OR REAGENTS REFER TO THE AUTOTECHNICON ULTRA ONLY." Individual reagent ports or beakers marked as follows: "FIXATION DEHYDRATION/ STAINING"; dymo labels below identify reagent used (ie) Formalin; ABS ALC; Xycol, etc.)/ Paraffin units numbered 1-4; "AUTOTECHNICON/ PARAFFIN BATH"; "MODEL 2C" and "SERIAL NO." cast in raised print on each container. "115.- 80 W." and individual serial numbers (top left to right- GG 229929; GG 220929; GG 227929; and GG 252929) printed on labels applied to beakers. All controls labelled. Electrical plugs connecting paraffin bath units to processor marked: " HOSPITAL/ GRADE ". " AUTOTECHNICON " appears twice, in raised print, on top piece of unit casing.
Missing
NONE
Finish
SQUARE GREY BASE FITTED WITH 2 CLEAR PLEXI-GLASS DOORS. UPRIGHT SUPPORTS, ROUND SUPPORTING STRUCTURES FOR CHEMICAL PORTS, & UPPER COVER ALL OF BRUSHED SILVER METAL. REAGENT CONTAINERS PRESUMABLY WERE OFF-WHITE - NOW VARIOUS COLOURS DETERMINED BY CONTENTS
Decoration
N/A

CITE THIS OBJECT

If you choose to share our information about this collection object, please cite:

TECHNICON INSTRUMENTS CORP., Processor, tissue, circa 1979, Artifact no. 1986.0902, Ingenium – Canada’s Museums of Science and Innovation, http://collection.ingenium.ca/en/id/1986.0902.001/

FEEDBACK

Submit a question or comment about this artifact.

More Like This


...
Purifier, air

2007.0282.001

Object

...
Reader, meter

1998.0313.001

Object

No image available.
Needle

1982.0180.002

Object

...
Teleprinter

1998.0437.001

Object

...
Oxygen machin…

1972.0266.001

Object

...
Sharpener, mi…

1987.1229.001

Object

...
Diathermy mac…

1977.0014.001

Object

...
Bottle

1988.0996.006

Object

...
Needle

1982.0180.001

Object

...
Speaker

1977.0571.001

Object

...
Dental unit

1984.1226.001

Object

...
Incubator

1995.1013.001

Object

...
Bath, eye

1995.0872.001

Object

...
Plotting head

1993.0187.002

Object

...
Freezing unit…

1987.1230.001

Object

...
Microtome

1987.1228.001

Object

...
Infiltrator, …

1983.0006.001

Object

...
Relay unit

1978.0966.003

Object

...
Analyser, sle…

2000.0081.001

Object

...

X-14315

Archives

...
Dispenser kit…

1999.0141.001

Object

...
Reagent

1991.0345.001

Object

...
Coil, radio

2001.0217.002

Object

...
Coil, radio

2001.0217.004

Object

...
Tellurometer

1986.0885.001

Object

...
Scanner, ultr…

2000.0221.008

Object

...
Bottle, milk

1975.0818.001

Object

...
Respirator

1970.0038.001

Object

...
Camera, proce…

1996.0647.001

Object

...
Fuser

1982.0688.001

Object

...
Processor, pr…

1987.2145.001

Object

...
Coil, radio

2001.0217.003

Object

...
Coil, radio

2001.0217.005

Object

...
Processor

1987.1110.001

Object

...
Beaker

1984.0938.001

Object

...
Lid, box

2014.0156.012

Object

...
Hook

1968.0579.016

Object

...
Drive, tape

1988.0240.001

Object

...
Bath, eye

1979.0038.001

Object

...
Bath, eye

1979.0039.001

Object

...
Central proce…

1983.0071.002

Object

...
Cuff, protect…

1995.1013.004

Object

No image available.
Cuff, protect…

1995.1013.005

Object

No image available.
Cuff, protect…

1995.1013.006

Object

No image available.
Cuff, protect…

1995.1013.007

Object

...
Lancet

1972.0250.001

Object

...
Holder, roll …

1966.0051.001

Object

...
Feeder, paper

1984.0822.002

Object

...
Panel, switch…

1992.2666.003

Object

...
Lamp bulb, in…

2014.0175.004

Object

...
Lamp bulb, in…

2014.0175.005

Object

...
Lamp bulb, in…

2014.0175.006

Object

...
Lamp bulb, in…

2014.0175.007

Object

...
Lamp bulb, in…

2014.0175.008

Object

...
Lamp bulb, in…

2014.0175.009

Object

...
Lamp bulb, in…

2014.0175.010

Object

...
Camera

1985.0521.001

Object

No image available.
Bracket

1972.0266.003

Object

No image available.
Bracket

1972.0266.004

Object

No image available.
Bracket

1972.0266.005

Object

...
Antenna

2005.0183.001

Object

...
Arrester, lig…

1976.0345.001

Object

...
Processor, fo…

1994.0179.001

Object

...
Endoscope

2014.0176.001

Object

...
Endoscope

2014.0176.006

Object

...
Reagent

1991.0346.001

Object

...
Carrier, light

2014.0175.002

Object

...
Carrier, light

2014.0175.003

Object

No image available.
Tent

1972.0266.002

Object

...
Needle, desic…

1978.1106.001

Object

...
Dryer

2004.2043.001

Object

...
Calculator

1987.0934.001

Object

...
Receiver, clo…

1997.0303.001

Object

...
Coil, radio

1976.0190.001

Object

...
Lancet

1991.0315.001

Object

...
Receiver, rad…

1966.0554.001

Object

...
Bronchoscope

2014.0175.001

Object

...
Recorder, film

1987.1121.001

Object

...
Counter, traf…

2003.0216.001

Object

...
Thermometer

1995.1013.003

Object

...
Receiver, Aut…

2005.0191.001

Object

...
Controller

1998.0325.001

Object

...
Diathermy mac…

1983.0551.001

Object

...
Thermometer

1980.0146.001

Object

...
Finisher, gar…

1998.0144.001

Object

...
Diathermy mac…

2002.0071.001

Object

No image available.
Software

1992.1579.008

Object

...
Scale

1995.1013.002

Object

...
Osmometer

2001.0478.001

Object

...
Bottle, chemi…

2002.0657.001

Object

...
Typesetter

1997.0772.001

Object

...
Labeller, can

1990.0188.001

Object

...
Synchroscope

1989.0138.005

Object

...
Beacon, posit…

1985.0766.001

Object

...
Printer

2010.0304.008

Object

...
Monitor, video

2010.0304.004

Object

...
Splicer kit

1994.0459.001

Object

...
Positioning i…

2012.0035.001

Object

...
Vacuum tube

1967.1056.001

Object

No image available.
Software

1992.1579.005

Object